Natural Rubber is Polymer composed of Heavaprene and is obtained commercially from the rubber tree. Rubber is most elastic substance known and this elasticity permits maximum glove dexterity. Rubber insulating gloves are among the most important articles of personnel protection for electrical workers incorporating high dielectric and physical strength, flexibility and durability.
"Crystal" rubber insulating gloves with curved hand design give superior electrical protection and maximum comfort in high voltage work.
"Crystal" rubber insulating gloves have earned the reputation for superior performance and meeting and exceeding requirements of tropical Indian conditions.
Under rigid quality control standards "Crystal" combines the finest raw materials and technical knowledge to produce line-men 's protective equipment that consistently surpasses ISS 4770/1968/1991/1993 and IEC 60903 specifications.
"Crystal" gloves are soft and flexible for comfort yet both abrasion and cut resistant for long wear.
Production facilities for manufacturing "Crystal" electrical lineman's gloves comply with the highest possible standards and regulations.
"Crystal's" exclusive finish helps always slip on hand and off easily and gives comfortable pleasant feel to the wearer.
"Crystal" gloves increase workplace safety.
Each & Every pair of "Crystal" brand Electrical Gloves are tested in Our Plant & Laboratory to IS Specification No. 4770/1991/1993 & IEC 60903 for
Test Potential
Lekage Current
Physical Properties
Thus, Guaranteeing full protection and satisfaction to users.
To Optimize the use of the "Crystal" Lineman's Gloves, It is recommended to follow conditions below:
"Crystal" Brand Regd. Trade Mark No 340716
Seamless Latex Hand Gloves For Electrical Purpose
TEST POTENTIAL (VOLTS) | WORKING POTENTIAL (VOLTS) | SIZE (mm) |
---|---|---|
5000 | 650 | 355 |
10000 | 1100 | 355 |
11000 | 1100 | 355 |
15000 | 3300 | 355 |
20000 | 4000 | 355 |
22000 | 4000 | 355 |
25000 | 5000 | 355 |
33000 | 7500 | 380 |
33000 | 11000 | 380 |
TYPE | TEST VOLTAGE VOLTS / FOR 1 MIN. | WORKING POTENTIAL (VOLTS) |
---|---|---|
TYPE 1 | 5,000 VOLTS | 650 VOLTS |
TYPE 2 | 10,000 VOLTS | 1,100 VOLTS |
TYPE 3 | 15,000 VOLTS | 3,300 VOLTS |
TYPE 4 | 20,000 VOLTS | 4,000 VOLTS |
TYPE | TEST VOLTAGE VOLTS / FOR 1 MIN. | WORKING POTENTIAL (VOLTS) |
---|---|---|
- | 17,000 VOLTS | 7,500 VOLTS |
TYPE | TEST VOLTAGE VOLTS / FOR 1 MIN. | WORKING POTENTIAL (VOLTS) |
---|---|---|
TYPE I | 5,000 VOLTS | 650 VOLTS |
TYPE II | 10,000 VOLTS | 1,100 VOLTS |
TYPE III | 17,000 VOLTS | 7,500 VOLTS |
TYPE IV | 25,000 VOLTS | 17,000 VOLTS |
TYPE | TEST VOLTAGE VOLTS / FOR 3 MIN. | WORKING POTENTIAL (VOLTS) |
---|---|---|
00 | 2,500 VOLTS | 500 VOLTS |
0 | 5,000 VOLTS | 1,000 VOLTS |
1 | 10,000 VOLTS | 7,500 VOLTS |
2 | 20,000 VOLTS | 17,000 VOLTS |
3 | 30,000 VOLTS | 26,500 VOLTS |
4 | 40,000 VOLTS | 36,000 VOLTS |